|
|
||||||||
ORIGINAL CONTRIBUTION |
From the Kirksville College of Osteopathic Medicine of A.T. Still University of Health Sciences.
Address correspondence to Brian Degenhardt, DO, Director, A.T. Still Research Institute, A.T. Still University of Health Sciences, 800 W Jefferson St, Kirksville, MO 63501-1443. E-mail: bdegenhardt{at}atsu.edu
Context: Establishing reliable palpatory tests continues to be a critical, yet elusive, step in osteopathic medical research and evidence-based clinical practice.
Objective: The authors investigated the interobserver reliability of common osteopathic palpatory tests used to evaluate the lumbar spine.
Design and Methods: Subjects (N=119) were recruited from the
faculty, staff, and students of Kirksville (Mo) College of Osteopathic
Medicine (KCOM) of A.T. Still University of Health Sciences. Three osteopathic
medical examiners residency trained in neuromusculoskeletal medicine initially
evaluated lumbar segments on subjects from one subgroup (n=42) in a blinded
assessment. The examiners performed palpatory tests of tenderness and tissue
texture changes, as well asin three planesvertebral positional
asymmetry and motion asymmetry. Kappa statistics (
) were used to
evaluate interobserver reliability. Following a period of consensus training,
subjects from another subgroup (n=77) were evaluated in a blinded assessment
for those palpatory tests that seemed most likely to produce reliable
findings. The interobserver reliability was then re-evaluated.
Results: During the initial evaluation of interobserver reliability,
ranged from -0.02 to 0.34, within the poor-to-fair reliability range.
Following consensus training, reliability improved, rising into the moderate
range for tissue texture changes (
=0.45) and into the substantial range
for tenderness assessments (
=0.68). Reliability for positional
asymmetry in the transverse plane (
=0.34) and rotational motion
asymmetry (
=0.20) were improved but remained in the fair range.
Conclusion: The authors concluded that consensus training improved
the interobserver reliability of common osteopathic palpatory tests of the
lumbar spine. In two of the four tests that were studiedtissue texture
and tendernessacceptable
values for clinical tests were
achieved after consensus training.
For palpatory tests, two forms of reliability are routinely studied: intraobserver reliability and interobserver reliability. Intraobserver reliability assesses the ability of a healthcare professional to obtain the same finding when serially evaluating a patient. This form of reliability has been criticized as lacking in credibility, mostly because of the difficulties in blinding an examiner between examinations.2 Interobserver reliability, the degree to which multiple examiners reach the same conclusion, is considered more relevant than intraobserver reliability in assessing practitioner skill.2 The current study investigated the interobserver reliability of three specialists in osteopathic neuromusculoskeletal medicine.
For at least 30 years, researchers of manual medicine have studied the reliability of many of the commonly used palpatory diagnostic tests.3 Most of the more than 200 published articles in this area failed to show a level of reproducibility that supports the use of palpation in evidence-based clinical practice. Many of these studies have been criticized for having inadequate research design.2,4-8 Among the studies that applied rigorous scientific methods, most of these studies reported that, while at least one palpatory test had reasonable reliability, most tests did not.9-13 Several reviews since the early 1990s have found that because of an insufficient number of well-performed studies, conclusions cannot be arrived at about the reliability of either static landmark position tests or passive motion tests.8,14,15 As a result, the scientific community continues to question the relevance of manually performed diagnostic tests.
A major criticism of previously performed research is the improper use of
statistical methods. Percent agreement, a method used to evaluate reliability
of categorical and ordinal ratings in many previous studies, does not account
for the amount of agreement that occurs by
chance.8 Thus,
percent agreement has been replaced by Cohen's kappa statistic (
) as
the preferred measure of the strength of reliability.
|
value may decrease because of
lack of observation variability. Landis and
Koch16 established
a scale for interpreting
values as follows: 0.81-1.00 indicates almost
perfect reliability; 0.61-0.80, substantial reliability; 0.41-0.60, moderate
reliability; 0.21-0.40, fair reliability; and less than 0.20, poor
reliability. When analyzing the results of subjects' physical examinations, a
value of at least 0.40 is considered an indicator of acceptable
interobserver
reliability.17 There are four general types of palpatory diagnostic tests commonly taught and used in clinical practice, including osteopathic medicine. Clinicians use these tests to perform the following evaluations:
In a systematic review, Hestbaek and Leboeuf-Yde15 reported that palpatory tests assessing tenderness have consistently shown at least moderate interobserver reliability. However, palpatory tests of landmark positional asymmetry, motion asymmetry, and tissue texture have consistently shown poor reliability. 5,11,13,15,21-23
We propose that acceptable interobserver reliability was not found in earlier studies of palpatory diagnostic tests for several reasons. First, human beings are not static entities. Homeostatic mechanisms, such as heart rate, respiratory rate, blood pressure, andespecially pertinent for the current study neuromotor reflexes are responsible for constant inherent neurophysiologic variability. The neuromusculoskeletal system changes on some level each second according to the impulses or stresses that individuals experience. This inherent neurophysiologic variability occurs in both the examiner and subject. The dynamic nature of the human body could thus challenge clinicians' abilities to reliably perform palpation because, by definition, reliability determines the reproducibility of findings when a test is repeated to evaluate an unchanged attribute. Second, some current educational systems may not provide students or clinicians with the necessary skills for reliably performing palpation. Third, because of the relative isolation of many private practices, experts in manual medicine may not perform palpatory procedures in similar ways, limiting the likelihood of reliability.
We hypothesized that examiners would have improved interobserver
reliability after participating in a rigorous consensus-training program.
Because palpation that induced repetitive motion would be more likely than
positional palpation to change the characteristics being examined, we also
predicted that positional asymmetry tests would require less training than
motion asymmetry testing to obtain at least moderate interobserver
reliability. In addition, this consideration led us to predict that
values for tests that induce motion would be lower than
values for
positional asymmetry tests.
| Methods |
|---|
|
|
|---|
The study was designed to determine which palpatory diagnostic tests of the lumbar spine demonstrated at least moderate interobserver reliability when performed by three examiners with osteopathic residency training in neuromusculoskeletal medicine. Most of the tests and the parameters used to interpret them were well established within the osteopathic medical profession.18-20 For manual tests that failed to show at least moderate interobserver reliability using the skills developed through basic and advanced osteopathic manipulative training, the examiners underwent consensus training to improve reliability prior to re-evaluating the tests.
Following test identification and definition, the experimental design consisted of the following three phases:
Three examiners (B.F.D.,K.T.S.,E.J.S.), who are members of KCOM's Department of Osteopathic Medicine, participated in this study. All three examiners had residency training in neuromusculoskeletal medicine and fewer than 10 years clinical experience in the specialty. A single-blinded method with examiners not blindedwas used for test identification\definition and for phase 2 of this study. The examiners collected data in a double-blinded method in phases 1 and 3. Only data collected in phases 1 and 3 were used in the statistical analyses.
Test Identification and Definition
In the test identification and definition part of the current study,
examiners determined which palpatory diagnostic tests commonly used to
evaluate lumbar segments L1 through L4 should be included in the study.
Evaluation of the L5 vertebral segment was not included in the study because
of the significant anatomic variability in size, shape, and relative positions
of L5 and the ilium and sacrum.
The examiners reviewed standardized descriptions of the tests (Figure 1) and parameters for interpreting those tests. The tests consisted of assessments of tenderness and tissue texture changes, as well as evaluations of positional and motion asymmetry in three planes (coronal, sagittal, and transverse).
Although preferred methods for most of the palpatory tests have long been agreed upon in the osteopathic medical profession,18-20 tests for positional asymmetry in the coronal plane and motion asymmetry in the sagittal plane are not well established. Therefore, the examiners agreed upon methods for these tests that appeared consistent with the models used to test vertebral motion in other reference planes.
To test for positional asymmetry in the coronal plane with the subject in the prone position, thumbs were placed in the interspaces between the transverse processes of two adjacent vertebrae. Gradual cephalad motion was performed until a firm barrier was noted to indicate that the thumbs were on the under surfaces of the transverse processes. The diagnosis was based on the relative position of the transverse processes compared to the neutral position (ie, right thumb inferior for side-bending to the right). To test for flexion motion preference in the sagittal plane, seated subjects were bent forward, and anterior springing motion was induced on both transverse processes simultaneously. To determine extension motion preference, prone patients arched their backs and rested on their elbows in a sphinxlike position. Examiners used their thumbs to apply pressure on the transverse processes, augmenting extension.
Phase 1: Pretraining Interobserver Reliability Assessment
Forty-two healthy subjects between the ages of 20 and 44 years (mean age,
26 years [SD±4]) were recruited for phase 1 of the current study from
the faculty, staff, and students of KCOM. Thirty-one (74%) men and 11 (26%)
women participated in phase 1 of the current study.
Subjects were placed in 14 groups of three subjects. The three examiners worked simultaneously in each training session, providing physical examinations to one group of subjects per session. These sessions took a total of approximately five hours and were spread over four days. This phase of the study was conducted in a double-blinded manner, with each examiner blinded to the findings of the other two examiners.
Examiners asked subjects either to lie in the prone position (for most tests) or bend forward in the seated position (for some tests of motion asymmetry in the sagittal plane), depending on the test being performed, and to refrain from extraneous movements until the physical examination was complete. Each of the three examiners performed all eight palpatory tests on one subject in each group and recorded the presence or absence of physical findings after each examination. Each examiner repeated palpatory tests up to three times until that examiner determined a consistent finding.
The results of each test were analyzed based on variants of
statistics for two and three examiners, corresponding 95% confidence intervals
(CI), and percent agreement. The prevalence of the findings in the sample was
calculated as a weighted proportion in which the weights were based on the
number of examiners indicating vertebrae were positive for a given palpatory
finding. The results were reviewed, and those tests with a
value of
less than 0.40 were considered for further study in phases 2 and 3.
Phase 2: Consensus Training
For one to two hours a week over a four-month period, the three examiners
performed a protocol designed to promote consensus, focusing on one test at a
time. Initially, examiners evaluated subjects simultaneously, observing each
other's testing procedures. The subjects remained motionless in the prone
position during these examinations.
When each examiner expressed confidence that adequate modifications had been made to his or her technique to improve reliability, the examiners performed blinded examinations on a limited number of subjects to determine if progress had been made. Once a high percent agreement was identified for a particular test, consensus training was continued with the next test.
Phase 3: Posttraining Interobserver Reliability Assessment
For each of the tests used in phase 2, interobserver reliability was
reassessed using 15 to 33 new subjects. The precise number of subjects used
depended on the testing method under investigation; more subjects were used if
the examiners believed a test needed more work to achieve acceptable
reliability. All these new subjects came from a group of 77 individuals, also
healthy and between the ages of 20 and 65 (mean age, 31 [SD±8]), who
were also recruited from KCOM's faculty, staff, and students. Thirty (39%) men
and 47 (61%) women participated in phase 3 of the study.
Consistent with the protocol used in phase 1, groups of three subjects were examined simultaneously, each examiner evaluating one subject at a time in a blinded manner. Once an examination was completed, the examiners switched positions until all subjects had been examined. The subjects remained still in the prone position throughout testing.
When examiners performed palpatory tests assessing positional asymmetry and tissue texture on the subjects in a group, they always tested positional asymmetry first. The examiners performed the other two tests on separate days. Because of scheduling conflicts, only two of the three examiners (B.F.D.,K.T.S.) performed the test for tenderness. In these circumstances, only two subjects were examined at a time. Phase 3 testing took seven hours, which were spread over a six-day period.
After completing tests on each set of three subjects, the examiners scanned the subjects' data forms, identifying cases in which examiners had diagnosed opposite findings. If opposite findings were diagnosed for a vertebra, each examiner would re-evaluate that specific vertebra while the other examiners closely watched how the test was being performed. Through observation and subsequent discussion, a reason for each diagnostic variation was determined, and the testing procedures were modified if necessary.
As noted, data in phase 3 were collected in a double-blinded method and
analyzed based on variants of
for two and three examiners,
corresponding 95% CI, and percent agreement. Likewise, the prevalence of the
findings in the sample was calculated as a weighted proportion in which the
weights were based on the number of examiners who indicated the vertebrae were
positive for given palpatory findings. Logistic regression models were used to
test for change in the probability of agreement between examiners from
preconsensus to postconsensus training.
| Results |
|---|
|
|
|---|
=0.34). All other palpatory tests studied demonstrated
slight to poor interobserver reliability (
<0.20)
(Figure 2).
Tenderness, tissue texture changes, and transverse plane tests (motion
asymmetry and positional asymmetry) had the highest
values, indicating
the greatest likelihood for improvement of interobserver reliability with
consensus training.
|
In phase 2, consensus training was performed for those palpatory tests with the highest interobserver reliability. Tests for static landmark position asymmetry, tissue texture changes, and tenderness together took a total of three sessions of training until the examiners felt confident that their interobserver reliability values had adequately improved. These sessions began with the examiners simultaneously evaluating one subject. The examiners observed each other's performance of the test and then discussed observed variations in their techniques. This process allowed for the examiners to refine and perform their techniques in a standard manner.
Once the examiners were confident that their technique had been standardized, blinded examinations were performed on one subject. Immediately afterward, the findings of the different examiners were compared. For each vertebra that was a subject of disagreement, each member of the team repeated the test with the other examiners observing. Further discussion ensued to further refine technique and establish consensus.
The examiners spent 12 sessions over three months trying to establish reliability on the test assessing rotational motion. However, despite single-blinded interactions, interobserver reliability did not improve for this test.
To better understand the mechanics of each examiner's testing style, one examiner's thumbs rested passively on the tips of a subject's transverse processes while another examiner performed motion testing through the thumbs of the first examiner. Although initially useful, continued experimentation suggested that this training approach was unlikely to prove significantly beneficial. In recognition of the importance of motion asymmetry testing to osteopathic medicine, the motion testing protocol was changed to an anterior-posterior translational springing of the lumbar spinous processes, which proved to be of greater benefit during training.
|

0.40), for tests of tenderness (preconsensus
training
=0.32, postconsensus training
=0.68; P=.02)
and tissue texture (preconsensus training
=0.12, postconsensus training
=0.45; P=.003). Although interobserver reliability was
significantly improved for positional asymmetry in the transverse plane
(preconsensus training
=0.17, postconsensus training
=0.34;
P<.001), adequate interobserver reliability was not obtained
(
=0.40). By adapting the test for motion asymmetry in the transverse
plane to anterior-posterior translational springing of the lumbar spinous
processes, interobserver reliability improved (preconsensus training
=0.10, postconsensus training
=0.20; P=.04), but it did
not reach an adequate level.
|
|
|
| Comment |
|---|
|
|
|---|
For two of these palpatory tests (tissue texture changes and tenderness assessment), interobserver reliability improved from fair or poor reliability to substantial or moderate reliability, respectively. The other two tests (assessing vertebral positional asymmetry and motion asymmetry) showed improvement from poor to fair reliability.
A qualification in the interpretation of the results of this study must be noted, however. The demographic characteristics of the subject pool may have influenced the results of the study. There were age and gender differences between the pretraining and posttraining groups. For example, in the pretraining group (phase 1), mean subject age was 26, and 74% of the subjects were men. In the posttraining group (phase 3), mean subject age was 31, and 39% of the subjects were men. In addition, the subjects' body mass indices, which could have played a role in the results, were not recorded. Thus, it is possible that the interobserver reliability changes observed in the current study were secondary to these demographic and physical differences, rather than being the result of consensus training. In future studies, investigators may wish to use the same group of subjects in both the preconsensus and postconsensus trials.
These cautions are somewhat mitigated by the fact that all the subjects
(N=119) were young (mean age, 29 years [SD±7]). Such subjects would be
expected to have less severe and less frequent somatic dysfunctions compared
with typical patients of osteopathic family physicians. By studying younger
and healthier subjects than those who seek medical intervention, the examiners
in this study may have evaluated individuals who have less somatic dysfunction
and possibly more reactive neuromusculoskeletal reflexes than the typical
patient. As a result, palpatory findings may have changed during the
repetitive diagnostic process. If these assumptions are true, the
values determined in this study would be lower than what would probably occur
in the typical clinic setting.
It would be beneficial for further investigations to examine subjects throughout all stages of life, evaluating palpatory tests for all relevant regions of the body and enrolling a significant number of individuals who are symptomatic and have clinically meaningful dysfunction. Such a study design is likely to produce a more conclusive definition or demonstration of the reliability of osteopathic palpatory testing methods.
The poor
scores obtained in phase 1 may have resulted from at least
two confounding factors: inappropriate methodology and limitations in the
training of the examiners. During phase 1, each examiner performed eight tests
on one subject before moving to the next subject. Each test was performed two
or three times until the individual examiner was confident of that test's
outcome. As a result, each vertebra was tested between 48 and 72 times. Thus,
changes in the subjects' neuromusculoskeletal systems secondary to repetitive
stimuli may have been one reason for poor reliability in phase 1 of the
study.
Another methodological issue that arose during phase 1 is that the subjects had to change position for each examiner so that all the tests could be performed sequentially. Consequently, variations in subject position from the first examiner to the two subsequent examiners could have been an additional confounding factor. Examiners addressed both of these issues in phases 2 and 3 of the study by requesting that subjects remain in the same prone position throughout the testing sequence. In addition, in phases 2 and 3, each vertebra was tested no more than 18 times by the examiners.
In phase 2, the consensus training for nonmotion palpatory diagnostic tests consisted of only one training session per test. However, the test that induced vertebral motion in the transverse plane did not significantly improve in reliability even after 12 sessions of training. The examiners noted that motion characteristics routinely changed between one examiner's evaluation and the next. This experience supports the hypothesis that motion testing, which stimulates the sensory nervous system, may cause neuromotor reflexes to adapt to the stimuliespecially in young individuals like this study's subjectscausing findings to change after repetitive stimuli.
Also during phase 2, it was obvious that there were unique aspects of each examiner's technique. This variety would seem to indicate that the skills the examiners developed in their osteopathic medical educational programs or medical practices were notor were no longerstandardized.
The current study's research team excelled in palpatory skills during their undergraduate and graduate osteopathic medical education. All three examiners trained in the same two-year residency program in neuromusculoskeletal medicine and osteopathic manipulative medicine. Two had completed the program, and the third was in the final months of completing the program while participating in the current study. The ability to apply osteopathic palpatory diagnostic skills in a reliable, scientific format is most likely to exist among those physicians who have the greatest and most similar training in this area (board-certified and board-eligible, residency-trained osteopathic physicians). Nevertheless, the palpatory experts in the current study were initially unable to demonstrate moderate reliability of any of the tests performed. This inability was consistent with numerous previous studies in the literature.2-8
To address this problem and to better calibrate and standardize the
palpatory skills of future osteopathic physicians, osteopathic medical
educators need to critically evaluate the current methods by which palpatory
diagnostic skills are taught and reinforced in schools. The current study
suggests that to date, the curricula at osteopathic medical schools have not
been formatted to determine the interobserver reliability skills of each
graduating student. Although the challenges in formatting and the logistics in
developing such curricula are understood, osteopathic medical educators need
to appreciate the importance of overcoming these obstacles. Testing formats
need to be revised to ensure that the baseline skills in palpatory diagnostics
for all osteopathic medical students have a level of reliability that would be
acceptable within the scientific community (
0.40).
One process for establishing improved training methods would be to identify those palpatory diagnostic tests that are most reliable in the hands of clinical researchers. Then those methods should be used as standard procedures in the teaching and testing of palpatory skills in osteopathic medical schools. Once adequate interobserver reliability for a test has been demonstrated by a group of researchers, clinicians, or students, the persistence of the test's interobserver reliability should be determined to establish whether that palpatory instrument can remain calibrated.
Although it is fundamental to the scientific process to establish reliable palpatory diagnostic tests, the significance of establishing appropriate levels of interobserver reliability is limited. Just because any number of clinicians can demonstrate moderate to substantial interobserver reliability of certain tests, one cannot generalize that these tests are reliable in the hands of all osteopathic physicians who perform them. Even if the osteopathic medical profession's colleges, internships, and residencies could establish programs that demonstrate the reliability of the performance of their graduates, reliability alone does not address issues concerning the accuracy, validity, and clinical impact of the palpatory tests used by these graduates. These are crucial issues that must be more aggressively studied.
| Conclusion |
|---|
|
|
|---|
| Acknowledgment |
|---|
This study was supported by the National Institutes of Health's National Center for Complimentary and Alternative Medicine (Grant No. 1R01AT00305-1) and the American Osteopathic Association (Grant No. 00-04-505).
| References |
|---|
|
|
|---|
2. Haas M. The reliability of reliability [review]. J Manipulative Physiol Ther.1991; 14:199 -208.[Medline]
3. Johnston WL. Interexaminer reliability studies: spanning a gap in medical researchLouisa Burns Memorial Lecture. J Am Osteopath Assoc. 1982;81:819 -829.[Medline]
4. Alley JR. The clinical value of motion palpation as a diagnostic tool: a review. J Can Chiropr Assoc.1983; 27:97 -100.
5. Russell R. Diagnostic palpation of the spine: a review of procedures and assessment of their reliability. J Manipulative Physiol Ther. 1983;6:181 -183.[Medline]
6. Keating JC Jr. Several strategies for evaluating the objectivity of measurements in clinical research and practice. J Can Chiropr Assoc. 1988;32:133 -138.
7. Keating JC Jr. Inter-examiner reliability of motion palpation of the lumbar spine: a review of the quantitative literature [review]. Am J Chiropractic Med.1989; 2:107 -110.
8. Haas M. Statistical methodology for reliability studies. J Manipulative Physiol Ther.1991; 14:119 -132.[Medline]
9. Mior SA, King RS, McGregor M, Bernard M. Intra- and interexaminer reliability of motion palpation of the cervical spine. J Can Chiropr Assoc. 1985;29:195 -198.
10. Boline PD, Keating JC Jr, Brist J, Denver G. Interexaminer reliability of palpatory evaluations of the lumbar spine. Am J Chiropractic Med. 1988;1:5 -11.
11. Mootz RD, Keating JC Jr, Kontz HP, Milus TB, Jacobs GE. Intra- and interexaminer reliability of passive motion palpation of the lumbar spine. J Manipulative Physiol Ther.1989; 12:440 -445.[Medline]
12. Keating JC Jr, Bergmann TF, Jacobs GE, Finer BA, Larson K. Interexaminer reliability of eight evaluative dimensions of lumbar segmental abnormality. J Manipulative Physiol Ther.1990; 13:463 -470.[Medline]
13. Jull G, Bogduk N, Marsland A. The accuracy of manual diagnosis for cervical zygapophysial joint pain syndromes. Med J Aust. 1988;148:233 -236.[Medline]
14. Panzer DM. The reliability of lumbar motion palpation [review]. J Manipulative Physiol Ther.1992; 15:518 -524.[Medline]
15. Hestbaek L, Leboeuf-Yde C. Are chiropractic tests for the lumbo-pelvic spine reliable and valid? A systematic critical literature review [review]. J Manipulative Physiol Ther.2000; 23:258 -275.[Medline]
16. Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics.1977; 33:159 -174.[Medline]
17. Fjellner A, Bexander C, Faleij R, Strender LE. Interexaminer reliability in physical examination of the cervical spine. J Manipulative Physiol Ther.1999; 22:511 -516.[Medline]
18. Dinnar U, Beal MC, Goodridge JP, Johnston WL, Karni Z, Mitchell FL Jr, et al. Classification of diagnostic tests used with osteopathic manipulation. JAm Osteopath Assoc.1980; 79:451 -455.
19. Dinnar U, Beal MC, Goodridge JP, Johnston WL, Karni Z, Mitchell FL Jr, et al. Description of fifty diagnostic tests used with osteopathic manipulation. J Am Osteopath Assoc.1982; 81:314 -321.[Medline]
20. Kuchera WA, Kappler RE. Musculoskeletal examination of somatic dysfunction. In: Ward RC, ed. Foundations for Osteopathic Medicine. 2nd ed. Philadelphia, Pa: Lippincott Williams and Wilkins; 2002: 633-659.
21. Love RM, Brodeur RR. Inter- and intra-examiner reliability of motion palpation for the thoracolumbar spine. J Manipulative Physiol Ther. 1987;10:1 -4.[Medline]
22. Spring F, Gibbons P, Tehan P. Intra-examiner and inter-examiner reliability of a positional diagnostic screen for the lumbar spine. J Osteopath Med (Australia).2001; 4:47 -55.
23. French SD, Green S, Forbes A. Reliability of chiropractic methods commonly used to detect manipulable lesions in patients with chronic low-back pain. J Manipulative Physiol Ther.2000; 23:231 -238.[Medline]
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |